Marvel 60CIM-SS-F Guide de dépannage Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 28
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
INSTALLING THE DRAIN PLUMBING
Drain Plumbing
Your ice machine uses a gravity drain (Figure 3) that re-
quires 5/8” I.D. tubing from the back of the ice machine
to a plumbed connection to a sanitary sewer. Remove the
access panel to plumb in drain connection. Gravity drain
location for built-in units can be within the area shown
in Figure 5. An optional drain pump (Figure 4) can be
purchased for your ice machine if a gravity drain is not ac-
cessible. See page 5 for optional drain pump installation.
Observe and follow all local codes when installing ice
machine.
Failure to use adequate drainage system will result in
surrounding water damage and/or poor ice production.
4
Figure 5
Drain
Access
Figure 4
Figure 3
Access
panel
Access
panel
1-1/2” Drain pipe
Vue de la page 4