INSTALLING THE DRAIN PLUMBING
Access
panel
Drain pipe, (not
provided)
Drain tubing, cut
to length and in-
stall in the drain
C
L
C
L
14
7
8"
(37.8 cm)
11
16"
(17mm)
1
1
4"
(3.2 cm)
4
17
32"
(11.5 cm)
21
1
2"
(54.6 cm)
Drain Plumbing
Your ice machine requires drain plumbing. There are 2
variations of ice machines in regards to the installation of
the drain plumbing, without a drain pump (gravity drain),
and with a drain pump.
Figure 9
Figure 8
Drain line coiled
and secured to
the back of the
unit
Uncoil the drain line, route
to an appropriate drain and
cut to the required length
Electrical Shock Hazard
Reasonable care and safe methods should be prac-
ticed. Do NOT work with energized electrical equip-
ment in a wet area. Read and follow the installation
instructions listed in this manual.
!
WARNING
!
CAUTION
Failure to use an adequate drainage system, will result in
surrounding water damage and/or poor ice production.
Figure 7
!
CAUTION
Observe and follow all local building codes
when installing this ice machine and drain
lines.
Water
supply
inlet
Drain access in
bottom of unit
4
3
32"
(10.4 cm)
Sanitary
trap
2
1
4"(5.7 cm)
5
1
8" (13 cm)
Gravity Drain (no drain pump):
The ice machine is shipped with the drain line installed,
coiled and secured to the back of the cabinet as shown
in Figure 7. It can be uncoiled, routed to an appropriate
drain and cut to length as required. Additionally there is the
provision of drain routing through the cut-out in the bottom
of the unit, (see the gray area in Figure 8). A drain can be
installed in this gray area with the drain line cut to a short
length and positioned into the drain as shown in Figure 9,
or if the ice machine is to be built-in, the drain tube could be
routed through a hole in the  oor in this gray area to a drain
below.
The gravity drain line must be routed no higher than 6"
(15.2 cm) off the  oor to assure proper drainage.
!
CAUTION
Vue de la page 5
1 2 3 4 5 6 7 8 9 10 11 ... 95 96

Commentaires sur ces manuels

Pas de commentaire

Universal-air-tools UT8000S38 - 3/8 manuals

Owner’s manuals and user’s guides for Tools Universal-air-tools UT8000S38 - 3/8.
We providing 1 pdf manuals Universal-air-tools UT8000S38 - 3/8 for download free by document types: User Manual






More products and manuals for Tools Universal-air-tools

Models Document Type
HP180LI User Manual   Universal Air Tools HP180LI User Manual, 4 pages
UT8011R - 1/2 User Manual   Universal Air Tools UT8011R - 1/2 User Manual, 4 pages
UT8012 - 1/2 SQ User Manual   Universal Air Tools UT8012 - 1/2 SQ User Manual, 4 pages
UT8018A User Manual   Universal Air Tools UT8018A User Manual, 4 pages
UT8355-RL User Manual   Universal Air Tools UT8355-RL User Manual, 4 pages